CTD2X5005AXXX  - Carlo Gavazzi Korea  Sales

BRAND Carlo Gavazzi
Product CTD2X5005AXXX
Description AC Current Transforme
Internal code IMP241856
Weight 1
Technical specification AC Current Transformer (max 30x10mmbus-bar) Type CTD-2X • Bus-bar type current transformer • 0.5 class, currents from 40 to 600 A • Integrated DIN-rail mounting holder • Removable panel fixing clips • 2 Bus-bar isolated fixing screws • Double screw terminals (up to 8-wire connections) • Sealable terminal block covers Product Description Ordering Key CTD-2X 200 5A XXX Cable/Bus-bar type current transformerwith DIN-rail/bus- bar and panel mounting facili- Type Selection ty. Rated primary currents from 40 A to 600 A. Model Primary current Secondary current Option Optional fixing kit: CTD-kit Primary current From 40 to 600A (Refer to Range Table) Input Specifications Secondary current 1A 5A Option XXX:none XTX:tropicalization Operating frequency45 to 65 Hz Max. system voltage0.72 kV Rated insulation level3 kV/1 min. @ 50 Hz Insulation class E (max 75°C) Short-time current rating Ith Typical 100 In /1 s Idyn 2.5 Ith The short-time thermal current Ith is anyway limited by the cable/ bus-bar size Extended current rating 120% Security factor (FS)≤ 5 (Class: 0.5, 1 and 3) General Specifications Standards According to EN60044-1 HousingABS, self-extinguishing: UL 94 V-0 MountingDIN-rail bus-bar and panelmounting Standard accessoriesTwo terminal blockscrews. Two cable/bus-bar fixingscrews. Two sealable terminal block covers. Two panelmounting fixingclips. Two plastic caps for cable/bus-bar fixingscrews. Optional accessoriesExtended fixing kit: CTD-kit Two panel mounting fixing clips. Six cable/bus-bar fixing screws. Six plastic caps for cable/bus-bar fixing screws. Special features 1 A secondary current, Tropicalization Working temperature-25°Cto +60°C (-13°F to 140°F) (R.H.< 90% non condensing @ 40°C) Storage temperature -30°Cto +70°C (-22°F to 158°F) (R.H.< 90% non condensing @ 40°C) Approvals CE, cUrus and CSA Connection Screw type Cablecrosssection areaFrom1.5 to 6 mm2 Min/Max screws tightening torque relevant to terminal blockscrews: From1 to 2 Nm Max screws tightening torque relevant to the cable/bus-bar fixingscrews: 0,3 Nm Protection degreeIP00 IP20(withsealable terminal block covers + wire terminals) Cablediameter Max. 24 mm Bus-bar size HorizontalMax. 32x5 30x10 25x20 mm Vertical Max. 25x12mm Weight From350 to 500 g

Please Contact Us to Order to offer competitive prices and delivery time for Carlo Gavazzi - CTD2X5005AXXX AC Current Transforme number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Korea Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Carlo Gavazzi

CTD12H15005AXXX

Current Transformer

CTD12H20005AXXX

Current Transformer

CTD12H25005AXXX

Current Transformer

CTD12H30005AXXX

Current Transformer

CTD12H40005AXXX

Current Transformer

CTD12V10005AXXX

Current Transformer

CTD12V15005AXXX

Current Transformer

CTD12V20005AXXX

Current Transformer

CTD12V25005AXXX

Current Transformer

CTD12V30005AXXX

Current Transformer

CTD12V40005AXXX

Current Transformer

CTD1X1005AXXX

Current Transformer

CTD1X1205AXXX

Current Transformer

CTD1X1255AXXX

Current Transformer

CTD1X1605AXXX

Current Transformer

CTD1X2005AXXX

Current Transformer

CTD1X2505AXXX

Current Transformer

CTD1X3005AXXX

Current Transformer

CTD1X505AXXX

Current Transformer

CTD1X605AXXX

Current Transformer

CTD1X705AXXX

Current Transformer

CTD1X755AXXX

AC Current Transformer

CTD1X805AXXX

Current Transformer

CTD2X1005AXXX

AC Current Transformer

CTD2X1205AXXX

AC Current Transformer

CTD2X1255AXXX

AC Current Transformer

CTD2X1505AXXX

AC Current Transformer

CTD2X1605AXXX

AC Current Transformer

CTD2X2005AXXX

AC Current Transformer

Other Category Brands

Contact us for request