BRAND | ARDETEM |
Product | PECA301 5A2 |
Description | . Signal Analyzer |
Internal code | IMP4958530 |
Custom code | 90303900 |
Technical specification | NETWORK ANALYZER ELECTRIC POWER SUPPLY: 230VAC Network: single-phase, three-phase equi- unbalanced 3/4 wires Input: CT: .../5A Programmable IT and TP reports 3 High brightness displays 15 Settings on 5 pages: U,V,I,f,cos,P,Q,S,Ea,Er... RS485 Modbus/Jbus digital output TR: 180 to 325ms Size: 96x144mm. TROPICALIZATION OPTION INCLUDED |
Discover the superior quality and performance of the ARDETEM PECA301 5A2 with Impexron GMBH in Korea . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The PECA301 5A2 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of PECA301 5A2 :
At Impexron GMBH , we offer the PECA301 5A2 at competitive prices and with the fastest delivery times across Korea . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the PECA301 5A2 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply ARDETEM products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Display / Detachable programming unit for all Ardetem devices
DRB-5 TPI DIN rail holder Connecting terminal / connector for Hat rail for the power supply and bus for two devices, a connector is required
Three-phase universal analyzer Disturbancen Three-phase universal analyzer interference 3 or 4 wire three-phase systems, reading out balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 backlit Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / 173V LL and 330V LN / 600V LL 2 programmable current areas A 0..1 and 0..5 A Universal power supply AC / DC Reaction time 40 ms (2 cycles) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU
TPIs 50 N F / I converter Ethernet single-channel frequency converter Input: contact, logic, Namur, NPN / PNP Analog output: 0 - 20 mA, 0 - 10 V PC programmable with software SUPERVISION via USB port or Ethernet
TPIs 12 transmitters with process input 1 analog output Transmitters with process input in 7.2 mm-housing Input: mA; mV; V 1 Analog output: 0 - 10 V; 0/4 - 20 mA active Power: 24 VDC PC programmable with software SUPERVISION via USB port
Universal phase analyzer Disturbancen AC universal analyzer for interference 3 or 4 wire three-phase systems, reading balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 with backlight Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / LN 173V LL and 330V / 600V LL 2 programmable current ranges 0 to 1 A and 0 .5 A Universal Power Supply AC / DC 40ms response time (2 periods) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU
TRM4 2A Universal three-phase analyzerUniversal three-phase analyzer3 or 4 wire three-phase systems, readingbalanced and unbalanced networksInput: Voltage 0 3 .150 VAC, 0 ... 500 VACOutput: 3 Current 0 .1 0 .5 A and A (automaticswitching)Universal power supply AC / DCResponse time 40ms (two periods)Outputs 2 x analog bipolar)PC programmable with software SUPERVISIONPossible options:Up to 5 programmable analog0 ... 20mA, 4 ... 20mA, 0 ... 5 mA two of thesebipolar)4 output relays without analog output, or 2Relay outputs with max. 2 analog outputsEthernetProfibus DP• Overload: 10 times the rated current for 10 seconds• 50 times rated current (EDF standard) for 60 ms
Display with bi-directional Process input, analog output + 2 relays Digital display 48 x 96mm, 4 digits bidirectional process input (mA, mV, V) mA output active and 2 relays Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION
Display 48 x 96mm with Universal Input + 2 relays in the output Digital display 48 x 96mm, 4 digits Universal input mA, V, temp. Potentiometer resistance 2 relays in the output Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION
Supervision programming tool Software to program the ARDETEM Devices including USB interface and connection cables
μCONSOLE LCD Display / Removable programming unit for all Ardetem devices
TPI 10 AR universal transmitter with Analog output and 2 relays TPI 10 AR Universal Input: current, voltage, temperature resistance Output: Analog (current / voltage), 2 relays Programmable with display / PC Universal power supply: 20-300 VDC / VAC
DIP400 with tropicalization option.
digital indicator universal power supply
electrical network analyzer
ELECTRICAL MEASURE CENTRAL Current input: 1A and 5 A AC Voltage input: 175 V and 600 V AC For all network types Graphical LCD with rear-lighting 28 measurable parameters: 3U, 3V, 3I, cos, f, F, P, Q, S, E... Display of the energies on 8 digits on a single line with automatic switching to the upper unit Automatic correction of the wiring Output: RS 485 Modbus/Jbus Universal power supply; 20 to 270 vac and 20 to 300 vdc Format: 96x96mm
Measurement of DC signals - Dimensions 96x96x108mm -LCD ,DC networks
Signal analyzer for electrical networks
INSULATION FAULT DETECTOR
programmable transmitter
AC MEASURE TRANSMITTERS - high insulation 4KV. Input 0-5A and standard output 4-20mA Galvanic partition: 4Kv Accuracy rating: <0.3% Power supply: 20 to 270 Vac and 20 to 300 Vdc
DC MEASURE TRANSDUCER / DC CONVERTER Input / input: 0-1000 VDC Output / output: 4-20 mA Galvanic partition / galvanic isolation: 2KV Accuracy rating / accuracy: 0.2% For DIN rail mounting / for DIN rail mounting Power supply / power supply: 20 ... 270 Vac and 20 ... 300 Vdc
TMP-HI-2 EXCITATION CURRENT TRANSDUCER ,I/P : 75A/100mV O/P : 4-20 mA AUX : 90-270 VAC, 88-350 VDC 2-WIRE SENSOR
Universal current and voltage transmitter
TPA-TRM-3-2A-3 - OBSOLETE, REPLACEMENT 20182 TRM4 2A
PROGRAMMABLE TRANSMITTER
TPI 302 SERIAL:0302-388- OBSOLETE, REPLACED BY TPI400
power converter
PROGRAMMABLE CONVERTER Input: mA,mV,V. Bidirectionnal current and voltage input up to +/- 300 V dc Accuracy rating: 0.1% Programmable scale factor Supply for 2-wire sensor Insulated analog output (voltage or current) For DIN rail mounting Programmable by software or µconsole (optional) Universal power supply: 20 to 270 vac and 20 to 300 vdc
A three-phase analyzer for synchronous networks Three-phase analyzer for synchronous networks DIN-rail mounting AC indicator for exchange or Three-phase systems Voltage input 0 1 .150 VAC, 0 ... 600 VAC + 20% 1 Current input 0 .1 0 .5 A or A (automatic switching) Spanungsversorgung Universal AC / DC Response time 40ms (two periods) 1 analogue output Programmable with Display (LCD μCONSOLE) or PC