BRAND | Notifier by Honeywell |
Product | AM-4000 |
Description | fire alarm module |
Internal code | IMP4000887 |
Technical specification | 4 loop loop addressed fire detection control unit for the management of addressed type systems. Each line allows the connection of 99 detectors and 99 modules. The control unit allows separate management of the gas detection. thanks to a specific interface module. that view it must take place on a remote terminal dedicated only to technical alarms. Exit controlled siren. relay outputs for general alarm and fault. Two serial outputs in the standard version with two other options via additional board. Standard outputs for 22 terminals and for PCs for download / upload programming. Optional outputs for ethernet connection (TCP / IP) and one USB for pc or printer. or an RS232 / 485 output for connection to NOTE-FIRE-NET. Graphic display with 8 rows by 40 columns. written programmable from 32 characters per point and 32 characters per zone. 150 areas geographical and 400 groups with logical operators (AND. OR. DEL. etc.). Archive of 999 events. Auto programming of lines with double address recognition. Signaling of need for maintenance for detectors. CPR certified in compliance with EN 54 parts 2 and 4. Power supply from 230Vac mains. power supply standard 2.7A. Auxiliary current at 24Vdc of 1A. Charging two batteries a 12Vcc from 17Ah. Dimensions: 483mm x 266mm x 111mm. |
Please Contact Us to Order to offer competitive prices and delivery time for Notifier by Honeywell - AM-4000 fire alarm module number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Korea Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Indication Circuit Module for Fire Fighting System
8 Loop Fire Alarm Control Panel - 020-738 - Analogue Addressable
indoicator
INTERFACE CARD PROTOCOL CEIABI FOR SIB-600
interface card
isolator
ISOLATOR FOR RIL411 NFXI-TDIFF
isolator
isolator
Notifier
Single Output Interface Module
monitoring module
Call Point
Addressable Call Point
Glass Call Point with Isolator
ISOLATOR MODULE
MODULE, OUTPUT, P/N M701E-240 PROVIDING 250VAC 5A RATED VOLTAGE FREE CONTACTS, BOTH NORMALLY OPEN AND NORMALLY CLOSED.
MODEL CP-651E DISCONTINUED, REPLACEMENT SD-851E
smoke detector
Notifier
panel
B501AP, Notifier standard ring bus detector base pure white
Smoke Detector Analogue Addressable With Isolator - Pure White
(Reported)
Smoke Detector