BRAND | Wika |
Product | EN 837-1 110435406 |
Description | Manometer - 0 to 10 Bar 160mm |
Internal code | IMP268713 |
Weight | 1 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Wika - EN 837-1 110435406 Manometer - 0 to 10 Bar 160mm number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Korea Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Pressure transmitter for general applications Model S-10 Specifications according data sheet: PE 81.01 Power supply: DC 10 (14) ... 30 V Wetted components: Stainless steel Housing: stainless steel Output signal: 4 ... 20 mA, 2-wire Measuring range: 0 ... 3000 psi Process connection: 1/4 NPT Accuracy: 0.5% of span Electrical connection: Angular connector DIN EN 175301-803 A, IP65 permissible fluid temperature: -30 ... + 100 ° C Power supply: 10 ... 30 V DC Occupancy electrical output: UB = 1, 2 = 0V
GAUGE,PRESSURE:-1 TO 3 BAR,100MM DIAL,1/2" MNPT,SS 1.4571 CASE,LIQUID FILLED,MODEL #233.50.100
(Digital display type DI35 Specifications according data sheet: AC 80.03 Dimensions: 96 x 48 x 148 mm Fastening: latchable screw element (mm wall thickness up to 50) Display: LED, 5 digits of -9999 ... 99999 Accuracy: depending on the input configuration Display accuracy: e.g. for standard signals +/- 0.02% of the measuring range +/- 1 Digit Special design features: Min .- / Max value memory and code-protected input lock Input: 2 inputs for standard signals (0/4 ... 20 mA, 0 ... 10 V) with the computation function (+ - x /) Alarm outputs: 2 relays (AC 230V 5A DC 30V 2A), freely programmable Power supply: AC 230 V, 50/60 Hz Transmitter supply: DC 24 V max. 50 mA Analog position signal output: 4 ... 20 mA Protection: IP54 (front), IP00 (back) Device configuration: factory settings, device is configured by the user Customs tariff number: 85312020)
with Alloy
transmitter,Input = dc 10 – 30,Output = 4 mA to 20 mA,S# 260339Y
(Stainless steel 316L)/mbar/ 2X1/2" NPT (with adaptor)/class 1.0
Stainless steel
Bourdon tube pressure gauge, stainless steel Security Design EN 837-1 Type: 233.30 Specifications according data sheet: PM 02.04 Accuracy: NG 63 Kl.1,6 NG 100/160 Kl.1,0 Measuring system: Stainless steel Case Filling: with Nominal size: 100 mm Measuring range: pressure-measuring range Display range: 0 ... 60 kg / cm2 Process connection: 1/2 NPT Connection position: bottom Window: Laminated safety glass Pointer: Pointer standard Accuracy class: 1.0 Material measuring system: measuring system 316L Filling medium Housing: Glycerine 99.7% Manometer standard: International (Europe) Manufacturers Logo: * * WIKA
“ WIKA” ELECTRONIC PRESSURE TRASNMITTERS WITH PIZORESISTIVE SENSOR
Converters S-10 1 / 2U - 1/0 BAR 4/20 MA
(Tube pressure gauge spring, stainless steel Security Design EN 837-1 Type: 233.30 Specifications according data sheet: PM 02.04 Measuring system: Stainless steel Case Filling: with Nominal size: 100 mm Measuring range: pressure-measuring range Display range: 0 ... 160 bar Process connection: 1/2 NPT Connection position: bottom Window: Laminated safety glass Pointer: Pointer standard Accuracy class: 1.0 Material measuring system: measuring system 316L Filling medium Housing: Glycerine 99.7% Manometer standard: International (Europe) Manufacturers Logo: * * WIKA)
Tube pressure gauge element, stainless steel Type Specifications according data sheet: PM 02.02 Measuring system: Stainless steel Case Filling: with Nominal size: 100 mm Display range: 0 ... 4 bar Process connection: G 1/2 B Connection position: bottom Window: Laminated safety glass Pointer: Pointer standard Accuracy class: 1.0 Material measuring system: measuring system 316L Filling medium Housing: Glycerine 99.7%
converter
Specifications according data sheet: PE 81.01 Power supply: DC 10 (14) ... 30 V Wetted components: Stainless steel Housing: stainless steel Output signal: 4 ... 20 mA, 2-wire Measuring range: 0 ... 160 bar Process connection: G 1/2 B Accuracy: 0.5% of span Electrical connection: Angular connector DIN EN 175301-803 A, IP65 permissible fluid temperature: -30 ... + 100 ° C Power supply: 10 ... 30 V DC Occupancy electrical output: UB = 1, 2 = 0V
two pens in the same product
Pressure transmitter for general applications Model S-10 Specifications according data sheet: PE 81.01 Power supply: DC 10 (14) ... 30 V Wetted components: Stainless steel Housing: stainless steel Output signal: 4 ... 20 mA, 2-wire Measuring range: 0 ... 600 bar Process connection: G 1/2 B Accuracy: 0.5% of span Electrical connection: Angular connector DIN EN 175301-803 A, IP65 permissible fluid temperature: -30 ... + 100 ° C Power supply: 10 ... 30 V DC Occupancy electrical output: UB = 1, 2 = 0V Customs tariff number: 90262020
AST G1 / 2B kt 6 22 * 56 MS 2.0401.20
(910.11 VENT Z / SPNMUF G1 / 2 DIN16271 -VA FORM A VALVE FOR PRESSURE GAUGE DIN 16271 FORM A DN4 PN400 INPUT: G1 / 2B OUTPUT: G1 / 2 clamping socket JAM: M20x1,5 MATERIAL: VENTILKOERPER / STEM bleed screw 20ST CHROME NICKEL STEEL GEM. SPECIFICATION 2154709 Accessories for pressure gauge Customs tariff number: 84818079)
Shut off Valve-Order No:9091157
Manometer
Pressure Transmitter
(Pressure gauges Transformer)
Pressure Transmitter Model A-10 For general Applications Specifications according data sheet: PE 81.60Messstoffberührte components: 316LGehäuse: 316LNichtlinearität: 0.5% BFSLEinheit: barDruckart: relative measuring range: 0 ... 250 barProzessanschluss: G 1/4 A according to DIN 3852-EDichtung: NBRzulässige medium temperature: 0 ... + 80 ° CAusgangssignal: 4 ... 20 mA, 2-wire Power: 8 ... 30 V
FROST PROTECTION THERMOSTAT
Bimetal thermometer, industrial version Specifications according data sheet: TM 52.01 Accuracy: Cl. 1 according to EN 13190 Housing: stainless steel Stem material: Stainless steel 1.4571 Type: A52.080, Size 80, back mount Design of connection: standard, connection established Range: 0 ° C ... 120 ° C Process connection: G 1/2 B Stem diameter: 6 mm Installation length L1: 80 mm Standard mark on the dial: * EN 13190 * Accuracy of the dial: * * CL.1
Bimetallic thermometer, Process Industry Series Specifications according data sheet: TM 53.01 Accuracy: Cl. 1 according to EN 13190 Housing: stainless steel Stem material: Stainless steel Type: A 5300, size 3 ", back mount (axial) Design of connection: standard, connection established Unit: ° C Range: 0 ° C ... 250 ° C Process connection: G 1/2 B Stem diameter: 8 mm Installation length L1: 160 mm Window: Instrument glass
Transducer,0...45 bar 4...20 mA