BRAND | Bender |
Product | IRDH375B-425 |
Description | Insulation control device |
Internal code | IMP4973562 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Bender - IRDH375B-425 Insulation control device number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Korea Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
IRDH575B1W-435 3 (N) AC / DC20-575V A ISOMETER WITH LCD DISPLAY ALARM 1/2: 1KOhm-10MOhm, US: AC84-264V / DC77-286V, AMP MEßVERFAHR. Distribution installation housing 96x144mm (HxB) HISTORY MEMORY, REAL TIME CLOCK, POWER SEPARATION, BMS-INTERFACE, OUTPUT 0 (4) -20mA, WITH TESTER AND CONTROL FUNCTION FOR EDS SYSTEMS, test current 1-50mA ADDITIONAL PROCESSING "W"
IRDH575B1-4235 3 (N) AC / DC20-150V A ISOMETER WITH LCD DISPLAY ALARM 1/2: 1KOhm-10MOhm, US: AC84-264V / DC77-286V, AMP MESSVERFAHR. VOLTAGE 10V, FK-No.02 / 62 Distribution installation housing 96x144mm (HxB) HISTORY MEMORY, REAL TIME CLOCK, POWER SEPARATION, BMS-INTERFACE, OUTPUT 0 (4) -20mA, MIT test current GENERATOR AND CONTROL FUNCTION FOR EDS SYSTEMS, test current 1-50mA
AC0-800V / DC0-1000V ISOMETER MODULE PLATINUM VERSION, US: DC 12 ... 72 V OUTPUT: 0-10
AC0-800V / DC0-1000V ISOMETER MODULE PLATINUM VERSION, US: DC 12 ... 72 V, R-ON = 50Kohm Relay output (operating current)
Fixing kit
Connection kit
ISOLATIONSFEHLERSUCHGERÄT
2 ... 10MA, AC 100MA ... 10AISOLATIONSFEHLERSUCHGERÄTFÜR measuring current transformers W, WR, WSUS: DC / AC 42 ... 70 ... 460Hz 276V12 CHANNELS, LED display, BMS-INTERFACE2x1 CHANGER
EDS461-D-2 0.2 ... 1 mA, AC 10mA ... 1A INSULATION INSPECTION UNIT FOR MEASURING CURRENT TRANSFORMERS W / WS ..- 8000 US: DC / AC 42 ... 460Hz 70 ... 276V 12 channels, LCD, BMS-INTERFACE 2x1 CHANGER
INSULATION FAULT LOCATOR
W2-S70 CT FOR RCM MONITORS AND RCMS, EDS SYSTEMS, N-WIRE SURVEILLANCE
(AC0-460Hz / DC 0-7,2KV, ANKOPPELBAUSTEIN ONLY IN CONJUNCTION WITH IRDH275BM-7 .. Cable length 2 m)
(AC0-460HZ / DC 0-7,2KV, ANKOPPELBAUSTEIN ONLY IN CONNECTION WITH IRDH275BM-7 ..Cable length 0.5 mFK no. 09/42)
DC 24V UG-ISOMETER R-AN: 25K-OHM
107TD47 AC0-264V / U.S.: AC230V A-ISOMETE TO DIN VDE 0100-710, For healthcare centers ISO MONITORING: R-ALARM 50-500 KOHM LOAD MONITORING: I-ALARM 5-50 A (ONLY IN CONNECTION WITH STW2) TEMPERATURÜBERW. THERMISTOR DIN44081 LIGHTING. LCD DISPLAY, BMS-BUS RoHS Compliant
107TD47 AC0-264V / US: AC230V A-ISOMETE TO DIN VDE 0100-710, For healthcare centers ISOÜBERWACHUNG: R-ALARM 50-500 OHM LAST MONITORING: I-ALARM 5-50 A (ONLY IN CONNECTION WITH STW2) TEMPERATURÜBERW .: THERMISTOR DIN44081 LIGHTING. LCD DISPLAY, BMS-BUS
ESL0107/300 300VA AC230/23-28V 50-60Hz, SINGLE-PHASE ISOLATION TRANSFORMER TO DIN VDE 0551, SECURITY TRANSFORMER FOR OR LIGHTS, SEK.23/24/26/27/28V CU-WEIGHT 1.10 kg
Einphasen-Trenntransformator
Einphasen-Trenntransformator
voltage relays
voltage relays
voltage relays
Voltage relay
3 (N) AC 15-460HZ 0-500 / 288V AC / DC VOLTAGE RELAY, TRUE RMS, UNDER- AND TENSION: 6 ... 500/288 V UNDER- AND FREQUENCY: 15 ... 460 Hz ASYMMETRY: 5 ... 30% PHSENAUSFALL; PHASE SEQUENCE US: DC / AC 15 ... 460 Hz 70 ... 300 V START DELAY 0 ... 99 s
Undervoltage relay, SUR353Y 3 AC 400V 0.5-5 SEC
Residual current monitoring device
RCMA470LY AC / DC3 0mA-3A Allstrom. DIFFERENTIAL RELAY EXTERNAL CONVERTER W35B, W60B . LED RUN PUNK DANCE, RESPONSE 0-10s, US: AC230V
RCMA470LY AC/DC30mA-3A Allstrom. DIFFERENTIAL RELAY EXTERNAL CONVERTER W35B, W60B LED RUN PUNK DANCE., RESPONSE 0-10s, U.S.: AC230V
AC / DC100mA-3A Allstrom. DIFFERENTIAL RELAY EXTERNAL CONVERTER W3-A LED RUN PUNK DANCE., RESPONSE 0-10s, US: DC9,6-84V FK-NR. 96075
RESIDUAL CURRENT MONITORING DEVICE