BRAND | Hioki |
Product | PW3365-10 |
Description | CLAMP ON POWER LOGGER |
Internal code | IMP796502 |
Weight | 1 |
Technical specification | Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels Measurement items Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand Voltage ranges 400 V AC (Effective measurement range: 90.0 V to 520.0 V) Harmonic Harmonic voltage, harmonic current, voltage total harmonic distortion (THD-F or THD-R), current total harmonic distortion (THD-F or TDH-R), up to 13th order Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) Power ranges 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type) Basic accuracy Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020) Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1) Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) Save destination SD/SDHC Memory card, or internal memory at real time Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections Save items Measurement value save: Average only / Average, Maximum, Minimum value Screen copy: BMP form (saved every 5 min. at minimum interval time) Waveform save: Binary waveform data Interfaces SD/SDHC memory card, LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download, USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download Functions Connection check, Quick Set navigation guide, clock Power supply AC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter) Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off) |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Hioki - PW3365-10 CLAMP ON POWER LOGGER number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Korea Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
RS232 Interface Plate Plug-in for 3522_SOT 3S12-SO Attention! There is only 1 slot available. simultaneous operation with 95tB_01 (cPlB) iGicIT mdotich (documentation is available in English only)
PC Card 1GB
PC Card 2GB
Hioki AC/DC Current Sensor
Hioki 3532-50 Benchtop LCR Meter speed up to 5msec and 42Hz to 5MHz frequency range
Hioki 3532-50 Benchtop LCR Meter speed up to 5msec and 42Hz to 5MHz frequency range
Hioki 9234 Recording Paper For MR8880-20 8807 / 8808 / 8420s etc. (10rolls)
Hioki 9320-01 Logic Probe For 8807 / 8808 / 8847 / 8855 / 8860s / 8870
adapter
Hioki 9447 Battery Pack For 8807 / 8808s / 8420s
Hioki MR8880-20 Memory Hicorder
Hioki MR8880-20 Memory Hicorder
Hioki MR9000 Printer Unit For MR8880-20
Voltage Detector (multiple of 12)
Card HiTester Digital Multimet
AC/DC Clamp On Hi-Tester (TRMS) 1000A
Mega ohm test
Digital High Tester
Earth HiTester, 2 or 3 wire Measurements
3 Phase Power Analyzer
Digital Card Multi Meter
5kV Insulation Tester/Megohmmeter
High Voltage Insulation HiTester
LCR HiTester, Fourteen parameters, 42 Hz to 5 MHz
Battery HiTester
16ch Scan Unit TC/DC Volts (8860/61)
Test Fixture (Direct Connection Type)